Learning objectives
- 01Describe cardiac muscle cells and explain how intercalated discs make the myocardium a functional syncytium.
- 02Trace an impulse through the conduction system from the SA node to the Purkinje fibers and explain the purpose of the AV nodal delay.
- 03Compare the action potential of a contractile cardiac muscle cell with the pacemaker potential of an autorhythmic cell, and explain the significance of the plateau.
- 04Identify the waves, segments and intervals of a normal ECG and state the electrical event each represents.
- 05Relate pressure changes, volume changes, valve movements and heart sounds to the phases of the cardiac cycle.
- 06Define cardiac output and explain how preload, contractility, afterload and the autonomic nervous system change it.
Cardiac muscle cells
The myocardium is built from two kinds of cells. About 99 percent are contractile cells, which do the mechanical work of pumping. The remaining 1 percent are autorhythmic cells, which generate and distribute the electrical signal that makes the contractile cells contract.
Contractile cardiac muscle cells are striated like skeletal muscle fibers, because they contain the same sarcomeres, but they are short, branched, and usually have a single central nucleus. They are packed with mitochondria, because the heart depends on aerobic metabolism.
The ends of neighboring cells interlock at intercalated discs. Each disc contains two kinds of junction that explain how the heart behaves as a unit. Desmosomes rivet the cells together so that they do not pull apart during contraction. Gap junctions are protein channels that let ions pass directly from one cell to the next, so an action potential in one cell spreads to its neighbors. Because of the gap junctions, a whole chamber wall depolarizes and contracts together, as a functional syncytium. The heart has two of them, an atrial syncytium and a ventricular syncytium, separated by the non-conducting connective tissue of the fibrous skeleton.
The conduction system
Autorhythmic cells depolarize spontaneously, without any nerve supply. That is why a transplanted heart beats. The autorhythmic cells are organized into the conduction system, which sets the rhythm and makes sure the chambers contract in a useful order. An impulse travels through five components.
- The sinoatrial (SA) node lies in the wall of the right atrium just inferior to the opening of the superior vena cava. Its cells depolarize faster than any others, so it is the heart's normal pacemaker. From the SA node the impulse spreads through both atria by way of gap junctions, and the atria contract.
- The atrioventricular (AV) node lies in the inferior part of the interatrial septum. Its small fibers conduct slowly, delaying the impulse by about 0.1 second. The delay gives the atria time to finish emptying into the ventricles before the ventricles contract.
- The atrioventricular bundle (bundle of His) passes through the fibrous skeleton. It is the only electrical connection between the atria and the ventricles.
- The right and left bundle branches run down the two sides of the interventricular septum toward the apex.
- The Purkinje fibers (subendocardial conducting network) are large, fast fibers that turn upward from the apex and spread through the ventricular walls. Because excitation of the ventricular walls begins near the apex, contraction wrings blood upward toward the semilunar valves.
Every part of the system can pace the heart, but each is slower than the one before it.
| Pacemaker | Approximate intrinsic rate (per minute) |
|---|---|
| SA node | 100 (slowed to about 75 at rest by the vagus nerves) |
| AV node | 40 to 60 |
| AV bundle, bundle branches and Purkinje fibers | 20 to 40 |
The fastest pacemaker drives the rest. If the SA node fails, the AV node takes over at its own slower rate.
Schematic frontal section in anterior view, so the right side of the heart is on the left of the drawing. Valves are omitted.
Select a numbered structure to see what it is and what it does.
Cardiac action potentials
Autorhythmic cells have no stable resting potential. After each action potential their membrane potential drifts upward from about -60 mV as positive ions leak in. This slow drift is the pacemaker potential. When it reaches threshold, near -40 mV, voltage-gated Ca²⁺ channels open and the inflow of Ca²⁺ produces the rising phase of the action potential. Opening of K⁺ channels then repolarizes the cell, and the drift begins again. The steeper the pacemaker potential, the sooner threshold is reached and the faster the heart rate.
Contractile cells behave differently. They rest at about -90 mV until an impulse arrives through gap junctions. Their action potential has three phases.
- Rapid depolarization. Fast voltage-gated Na⁺ channels open, Na⁺ rushes in, and the membrane potential shoots to about +20 mV.
- Plateau. Slow voltage-gated Ca²⁺ channels open and Ca²⁺ flows in, while some K⁺ flows out. The two currents nearly balance, so the membrane stays depolarized for about 0.2 second. The entering Ca²⁺ triggers release of much more Ca²⁺ from the sarcoplasmic reticulum, and this Ca²⁺ binds troponin and starts contraction.
- Repolarization. The Ca²⁺ channels close, more K⁺ channels open, and K⁺ outflow returns the cell to its resting potential.
The plateau makes the cardiac action potential roughly a hundred times longer than that of a skeletal muscle fiber, and it gives the cell a long refractory period that lasts almost as long as the contraction itself. A second contraction cannot be triggered until the first is nearly over, so cardiac muscle cannot summate into tetanus. A heart in tetanus could not relax and refill, so this property is essential to its function as a pump.
Left: the action potential of a ventricular contractile cell. Right: two cycles of an SA node cell, which has no stable resting potential.
Select a numbered structure to see what it is and what it does.
The electrocardiogram
The currents generated by millions of cardiac cells depolarizing and repolarizing together can be detected by electrodes on the skin. The recording is an electrocardiogram (ECG). It shows the summed electrical activity of the whole heart, not a single action potential and not contraction itself. A normal beat produces three deflections.
- The P wave is atrial depolarization, spreading from the SA node. The atria contract shortly after it begins.
- The QRS complex is ventricular depolarization. Atrial repolarization happens at the same time and is hidden by it.
- The T wave is ventricular repolarization. It is broader than the QRS complex because repolarization is slower than depolarization.
The spacing between the waves is as informative as the waves themselves.
| Measurement | From, to | What it reflects |
|---|---|---|
| PR (PQ) interval | Start of the P wave to the start of the QRS complex | Conduction from the atria through the AV node to the ventricles; normally 0.12 to 0.20 s |
| ST segment | End of the QRS complex to the start of the T wave | The plateau, when the whole ventricular myocardium is depolarized |
| QT interval | Start of the QRS complex to the end of the T wave | Ventricular depolarization through repolarization |
| RR interval | One R wave to the next | One cardiac cycle; used to calculate heart rate |
A lengthened PR interval points to slowed conduction through the AV node. An ST segment displaced above or below the baseline suggests myocardium that is short of oxygen or injured.
Two beats of a normal ECG. The waves, one segment and the intervals of the first beat are marked.
Select a numbered structure to see what it is and what it does.
The cardiac cycle
One cardiac cycle is all the events of one heartbeat: systole (contraction) and diastole (relaxation) of the atria, then of the ventricles. At a resting rate of 75 beats per minute it lasts 0.8 second. Two rules explain every event. Blood flows from higher pressure to lower pressure, and each valve opens or closes passively according to the pressure difference across it. The values below are for the left side of the heart. The right side does the same at much lower pressures.
- Ventricular filling. The ventricles are relaxed and their pressure is lower than atrial pressure, so the AV valves are open and blood flows through the atria into the ventricles. Most filling is passive. At the end of this phase atrial systole, which follows the P wave, pushes in the last 20 percent or so. The volume in each ventricle is now the end-diastolic volume (EDV), about 130 mL.
- Isovolumetric contraction. Following the QRS complex the ventricles begin to contract. Ventricular pressure rises above atrial pressure and the AV valves close. For a moment all four valves are closed, so pressure climbs steeply while volume stays constant.
- Ventricular ejection. When left ventricular pressure exceeds aortic pressure, about 80 mm Hg, the semilunar valves open and blood is ejected. Pressure peaks near 120 mm Hg. About 60 mL remains in the ventricle afterward, the end-systolic volume (ESV).
- Isovolumetric relaxation. After the T wave the ventricles relax. As ventricular pressure falls below aortic pressure, blood starts to flow back toward the heart and closes the semilunar valves. The brief rebound of aortic pressure as the valve snaps shut is the dicrotic notch. All four valves are again closed until ventricular pressure falls below atrial pressure, the AV valves open, and filling starts again.
One cycle at 75 beats per minute, beginning with atrial systole. Top: pressures. Middle: left ventricular volume. Bottom: ECG. The vertical bands are the phases of the cycle.
Select a numbered structure to see what it is and what it does.
Heart sounds
A stethoscope picks up two sounds in each cardiac cycle, both produced by turbulence in the blood when valves close. The first heart sound (S1), "lubb", is the closing of the AV valves at the start of ventricular systole. The second heart sound (S2), "dupp", is the closing of the semilunar valves at the start of ventricular diastole. Systole is therefore the interval between S1 and S2, and diastole is the longer pause between S2 and the next S1.
Healthy valves open silently, and blood normally flows smoothly. A murmur is an abnormal swishing sound caused by turbulent flow, most often through a valve that does not open fully or does not close completely. The timing of a murmur within the cycle shows which valve fault is responsible.
The two AV valves, whose closure produces the first heart sound, with the papillary muscles that restrain their cusps, and the pulmonary valve, which closes together with the aortic valve to produce the second heart sound. The model has no separate mesh for the aortic valve.
Select a numbered structure to see what it is and what it does. Drag to rotate, scroll to zoom.
Cardiac output and its regulation
Stroke volume (SV) is the volume ejected by one ventricle in one beat: SV = EDV - ESV, about 70 mL at rest. Cardiac output (CO) is the volume ejected by one ventricle each minute:
CO = heart rate x stroke volume = 75 beats/min x 70 mL/beat = 5.25 L/min
During exercise cardiac output can rise several times over. The difference between maximal and resting output is the cardiac reserve.
Three factors set stroke volume.
- Preload is the stretch of the ventricular wall just before it contracts, set by the EDV. Within limits, the more the fibers are stretched, the more forcefully they contract. This is the Frank-Starling law of the heart. It matches output to venous return and keeps the outputs of the two ventricles equal.
- Contractility is the strength of contraction at a given preload. Sympathetic stimulation and epinephrine raise it by making more Ca²⁺ available inside the cells, which lowers the ESV.
- Afterload is the pressure the ventricle must overcome to open its semilunar valve. High arterial pressure or a narrowed valve raises afterload and reduces stroke volume.
Heart rate is adjusted by the cardiovascular center in the medulla oblongata, which receives input from baroreceptors, chemoreceptors and higher brain centers. Sympathetic cardiac accelerator nerves release norepinephrine at the SA node, the AV node and the ventricular myocardium. The pacemaker potential steepens, so the rate rises, and contractility increases. Parasympathetic fibers in the vagus nerves (CN X) release acetylcholine at the SA and AV nodes, which slows the pacemaker potential and lowers the rate. They have little effect on ventricular contractility. At rest vagal tone dominates, which is why the resting rate is below the SA node's intrinsic rate.
Structures to know
What you should be able to point to and explain on a lab practical.
Contractile cardiac muscle cellA short, branched, striated muscle cell of the myocardium, usually with one central nucleus and abundant mitochondria.
A short, branched, striated muscle cell of the myocardium, usually with one central nucleus and abundant mitochondria.
FunctionContracts to generate the pumping force of the heart. Contractile cells make up about 99 percent of cardiac muscle cells.
Intercalated discThe stepped junction between the ends of adjacent cardiac muscle cells, seen as a dark line across the fibers under the microscope.
The stepped junction between the ends of adjacent cardiac muscle cells, seen as a dark line across the fibers under the microscope.
FunctionIts desmosomes hold the cells together during contraction, and its gap junctions let action potentials pass from cell to cell.
FeaturesDesmosomes · Gap junctions
Autorhythmic (pacemaker) cellA specialized, non-contractile cardiac muscle cell of the conduction system that depolarizes spontaneously.
A specialized, non-contractile cardiac muscle cell of the conduction system that depolarizes spontaneously.
FunctionGenerates action potentials without outside stimulation and conducts them through the heart.
Sinoatrial (SA) nodeA cluster of autorhythmic cells in the wall of the right atrium, just inferior to the opening of the superior vena cava.
A cluster of autorhythmic cells in the wall of the right atrium, just inferior to the opening of the superior vena cava.
FunctionThe normal pacemaker of the heart. It starts each heartbeat and sets the sinus rhythm.
When the SA node fails, a slower part of the conduction system takes over as pacemaker. An artificial pacemaker may be implanted if the resulting rate is too slow.
Atrioventricular (AV) nodeA cluster of autorhythmic cells in the inferior part of the interatrial septum.
A cluster of autorhythmic cells in the inferior part of the interatrial septum.
FunctionDelays the impulse by about 0.1 second so that the atria finish contracting before the ventricles begin.
Damage to the AV node slows or blocks conduction to the ventricles (heart block).
Atrioventricular bundle (bundle of His)A short bundle of conducting fibers running from the AV node through the fibrous skeleton into the top of the interventricular septum.
A short bundle of conducting fibers running from the AV node through the fibrous skeleton into the top of the interventricular septum.
FunctionThe only electrical connection between the atria and the ventricles.
Right and left bundle branchesThe two divisions of the AV bundle, which run down the right and left sides of the interventricular septum toward the apex.
The two divisions of the AV bundle, which run down the right and left sides of the interventricular septum toward the apex.
FunctionCarry the impulse to the apex and to the right and left ventricles.
Purkinje fibers (subendocardial conducting network)Large-diameter conducting fibers that spread from the bundle branches at the apex upward through the ventricular walls, beneath the endocardium.
Large-diameter conducting fibers that spread from the bundle branches at the apex upward through the ventricular walls, beneath the endocardium.
FunctionConduct the impulse rapidly to the ventricular myocardium so that the ventricles contract almost simultaneously, beginning near the apex.
Fibrous skeleton of the heartDense connective tissue forming rings around the four valves, in the plane between the atria and the ventricles.
Dense connective tissue forming rings around the four valves, in the plane between the atria and the ventricles.
FunctionAnchors the valves and electrically insulates the atria from the ventricles, so that impulses can cross only through the AV bundle.
Tricuspid (right atrioventricular) valveThe three-cusp valve between the right atrium and the right ventricle.
The three-cusp valve between the right atrium and the right ventricle.
FunctionCloses when right ventricular pressure exceeds right atrial pressure, preventing backflow into the atrium. Its closure contributes to the first heart sound.
Mitral (left atrioventricular) valveThe two-cusp valve between the left atrium and the left ventricle.
The two-cusp valve between the left atrium and the left ventricle.
FunctionCloses when left ventricular pressure exceeds left atrial pressure, preventing backflow into the atrium. Its closure contributes to the first heart sound.
A mitral valve that fails to close fully lets blood leak back into the left atrium during systole, producing a systolic murmur.
Pulmonary valveThe semilunar valve at the outlet of the right ventricle, at the base of the pulmonary trunk.
The semilunar valve at the outlet of the right ventricle, at the base of the pulmonary trunk.
FunctionOpens during ventricular ejection and closes when ventricular pressure falls below pulmonary arterial pressure. Its closure contributes to the second heart sound.
Aortic valveThe semilunar valve at the outlet of the left ventricle, at the base of the ascending aorta.
The semilunar valve at the outlet of the left ventricle, at the base of the ascending aorta.
FunctionOpens when left ventricular pressure exceeds aortic pressure and closes when it falls below it. Its closure contributes to the second heart sound and produces the dicrotic notch.
A narrowed (stenotic) aortic valve raises the afterload on the left ventricle.
Papillary musclesCone-shaped projections of ventricular myocardium attached to the cusps of the AV valves by the chordae tendineae.
Cone-shaped projections of ventricular myocardium attached to the cusps of the AV valves by the chordae tendineae.
FunctionContract with the ventricles and tighten the chordae tendineae, which keeps the AV valve cusps from being pushed back into the atria during systole.
Cardiovascular centerA group of neurons in the medulla oblongata that receives input from baroreceptors, chemoreceptors and higher brain centers.
A group of neurons in the medulla oblongata that receives input from baroreceptors, chemoreceptors and higher brain centers.
FunctionAdjusts heart rate and contractility through sympathetic cardiac accelerator nerves and the parasympathetic vagus nerves.
Disorders and clinical correlations
Atrial fibrillation
A common arrhythmia in which the atria quiver in a rapid, disorganized way instead of contracting together.
Mechanism
Chaotic electrical activity in the atria replaces the orderly impulse from the SA node, so there are no P waves and no effective atrial systole. The AV node passes impulses to the ventricles at irregular intervals, which makes the pulse irregular. Because atrial contraction supplies only the last portion of ventricular filling, cardiac output falls only moderately. Blood stagnating in the quivering atria can clot, and a clot leaving the left atrium can lodge in a cerebral artery.
Signs and symptoms
- Irregularly irregular pulse
- Palpitations
- Fatigue and reduced exercise tolerance
- ECG without distinct P waves and with irregularly spaced QRS complexes
The main danger is stroke from an embolus formed in the left atrium.
Heart block (atrioventricular block)
Slowed or interrupted conduction of impulses from the atria to the ventricles.
Mechanism
The AV node and AV bundle are the only path across the insulating fibrous skeleton, so damage there isolates the ventricles from the SA node. In first-degree block every impulse gets through but slowly, which lengthens the PR interval. In second-degree block some impulses fail to get through, so some P waves are not followed by a QRS complex. In third-degree (complete) block none get through. The ventricles are then paced by the bundle or Purkinje fibers at 20 to 40 beats per minute, with no fixed relationship to the P waves.
Signs and symptoms
- Slow pulse
- Dizziness or fainting
- Fatigue and shortness of breath on exertion
- Prolonged PR interval or P waves not followed by QRS complexes on the ECG
Complete heart block is a common reason for implanting an artificial pacemaker.
Ventricular fibrillation
Uncoordinated electrical activity of the ventricles that abolishes their pumping action.
Mechanism
Different regions of the ventricular myocardium depolarize and contract out of step with one another, so the ventricles quiver without ejecting blood. Stroke volume, and therefore cardiac output, falls to nearly zero, and blood flow to the brain and to the heart muscle itself stops.
Signs and symptoms
- Sudden collapse and loss of consciousness
- No pulse
- Chaotic ECG with no recognizable QRS complexes
Defibrillation delivers a shock that depolarizes the whole myocardium at once, giving the SA node the chance to re-establish a normal rhythm.
Heart failure
A state in which the heart cannot pump enough blood to meet the body's needs.
Mechanism
A weakened ventricle ejects less blood, so its end-systolic volume rises and blood backs up in the circuit that drains into it. When the left ventricle fails, blood dams up in the pulmonary circulation, pulmonary capillary pressure rises and fluid leaks into the lungs. When the right ventricle fails, blood dams up in the systemic veins and fluid leaks into the tissues of the body. Failure of one side increases the load on the other, so one often leads to the other.
Signs and symptoms
- Left-sided: shortness of breath, worse when lying flat; cough and crackles from pulmonary edema
- Right-sided: swelling of the feet and ankles, distended neck veins, enlarged liver
- Fatigue and reduced exercise tolerance in both
Common causes include coronary artery disease, previous myocardial infarction, long-standing hypertension (high afterload) and valve disease.
Valve stenosis and regurgitation
Stenosis is a valve that is narrowed and does not open fully. Regurgitation (insufficiency) is a valve that does not close completely and leaks.
Mechanism
Blood forced through a narrowed opening, or leaking backward through a valve that should be shut, becomes turbulent and produces a murmur. The timing of the murmur follows from the cardiac cycle. Between S1 and S2 the semilunar valves should be open and the AV valves closed, so a systolic murmur indicates aortic or pulmonary stenosis or mitral or tricuspid regurgitation. After S2 the reverse holds, so a diastolic murmur indicates mitral or tricuspid stenosis or aortic or pulmonary regurgitation. A stenotic valve increases the pressure the chamber behind it must generate, and a leaking valve makes the chamber pump some blood twice. Either way the workload rises and the chamber may eventually fail.
Signs and symptoms
- Heart murmur
- Shortness of breath and fatigue on exertion
- Chest pain or fainting on exertion in aortic stenosis
- Signs of heart failure in advanced disease
Key terms
- Autorhythmicity
- The ability of certain cardiac muscle cells to depolarize spontaneously and rhythmically without nervous stimulation.
- Functional syncytium
- A mass of cells joined by gap junctions that depolarizes and contracts as a single unit, as the atrial and the ventricular myocardium each do.
- Pacemaker potential
- The slow, spontaneous depolarization of an autorhythmic cell that brings it to threshold.
- Plateau
- The prolonged depolarized phase of the contractile cell's action potential, maintained by Ca²⁺ inflow balanced against K⁺ outflow.
- Electrocardiogram (ECG)
- A recording, made from the body surface, of the summed electrical activity of the heart.
- Systole
- The contraction phase of a heart chamber.
- Diastole
- The relaxation phase of a heart chamber, during which it fills.
- End-diastolic volume (EDV)
- The volume of blood in a ventricle at the end of filling, just before it contracts; about 130 mL at rest.
- End-systolic volume (ESV)
- The volume of blood remaining in a ventricle after ejection; about 60 mL at rest.
- Stroke volume
- The volume of blood ejected by one ventricle in one beat, equal to EDV minus ESV.
- Cardiac output
- The volume of blood ejected by one ventricle per minute, equal to heart rate multiplied by stroke volume.
- Preload
- The degree of stretch of the ventricular myocardium at the end of diastole, determined by the end-diastolic volume.
- Afterload
- The pressure a ventricle must overcome to open its semilunar valve and eject blood.
- Frank-Starling law
- Within limits, the more the ventricle is stretched by filling, the more forcefully it contracts.
- Murmur
- An abnormal heart sound produced by turbulent blood flow, often through a stenotic or leaking valve.
Assessment
Check your understanding: Cardiac Conduction and the Cardiac Cycle
18 questions covering identification, function, mechanism, terminology, clinical application. Each answer comes with an explanation. Score 70% or better to complete the lesson.